Chiksan Catalog Archer Rental
Flow Control Reference Guide
The following recommendations for SPM flow control products are intended to be a guide to maximize efficiency, extended product life, and create a safer work environment.
Treating or discharge iron is produced for the following services: o Standard Service o H2S / Sour Gas Service o Low Temp Service
SPM ® recommends that you designate specific strings of iron for the following applications, and that the designated iron remain in that service application throughout the product’s life:
o Energized Fluids o Acids o Sour Gas o Low Temperature Applications
FLOW RATES ABOVE 42 FEET PER SECOND ARE NOT RECOMMENDED
Every string of iron should be pressurized to its maximum planned working pressure prior to each use.
Pressure seal line pipe threads are not recommended for pulsating service above 10,000 psi or where side loading or erosion are suspected. (Integral or Non-Pressure seal threads are recommended.)
Most flow control products are certified for the following temperature rating:
- Minimum: -30 ⁰ C - Maximum: 110 ⁰ C
Personnel must not be around pressure vessel products while pressure is present or being applied.
Each string, as well as each component, must have regular intervals of maintenance and inspection for safe, proper performance.
Never tighten or hammer wing unions when pressure is apparent.
Welding, brazing or heating on high pressure components is prohibited.
General maintenance will extend the life of flow control products.
- Grease plug valves and swivel joints after every job. - Replace seals to help prevent leaks and washouts of seal faces. - Clean all seal areas thoroughly. - Flush all products with water after each job.
Made with FlippingBook - Online catalogs